ip
ipku.in

IPv4 Subnet Calculator

Enter an IP with a CIDR prefix or a subnet mask to see its network, broadcast, host range, and host count. You can also split the network into smaller subnets.

$ ipcalc
private IP (RFC 1918)10.76.60.0/22
network10.76.60.0/22
broadcast10.76.63.255
first host10.76.60.1
last host10.76.63.254
subnet mask255.255.252.0
wildcard0.0.3.255
addresses1,024
usable hosts1,022
classA
ipcalc 10.76.60.0/22
address00001010.01001100.00111100.00000000
subnet mask11111111.11111111.11111100.00000000
network00001010.01001100.00111100.00000000
broadcast00001010.01001100.00111111.11111111
green = network part, grey = host part
hex0x0a4c3c00
decimal172768256
reverse dns0.60.76.10.in-addr.arpa
ipv4-mapped::ffff:a4c:3c00

/22 split into /30 · 256 subnets

close ×
#networkhost rangebroadcast
110.76.60.0/3010.76.60.1 – 10.76.60.210.76.60.3
210.76.60.4/3010.76.60.5 – 10.76.60.610.76.60.7
310.76.60.8/3010.76.60.9 – 10.76.60.1010.76.60.11
410.76.60.12/3010.76.60.13 – 10.76.60.1410.76.60.15
510.76.60.16/3010.76.60.17 – 10.76.60.1810.76.60.19
610.76.60.20/3010.76.60.21 – 10.76.60.2210.76.60.23
710.76.60.24/3010.76.60.25 – 10.76.60.2610.76.60.27
810.76.60.28/3010.76.60.29 – 10.76.60.3010.76.60.31
910.76.60.32/3010.76.60.33 – 10.76.60.3410.76.60.35
1010.76.60.36/3010.76.60.37 – 10.76.60.3810.76.60.39
1110.76.60.40/3010.76.60.41 – 10.76.60.4210.76.60.43
1210.76.60.44/3010.76.60.45 – 10.76.60.4610.76.60.47
1310.76.60.48/3010.76.60.49 – 10.76.60.5010.76.60.51
1410.76.60.52/3010.76.60.53 – 10.76.60.5410.76.60.55
1510.76.60.56/3010.76.60.57 – 10.76.60.5810.76.60.59
1610.76.60.60/3010.76.60.61 – 10.76.60.6210.76.60.63
1710.76.60.64/3010.76.60.65 – 10.76.60.6610.76.60.67
1810.76.60.68/3010.76.60.69 – 10.76.60.7010.76.60.71
1910.76.60.72/3010.76.60.73 – 10.76.60.7410.76.60.75
2010.76.60.76/3010.76.60.77 – 10.76.60.7810.76.60.79
2110.76.60.80/3010.76.60.81 – 10.76.60.8210.76.60.83
2210.76.60.84/3010.76.60.85 – 10.76.60.8610.76.60.87
2310.76.60.88/3010.76.60.89 – 10.76.60.9010.76.60.91
2410.76.60.92/3010.76.60.93 – 10.76.60.9410.76.60.95
2510.76.60.96/3010.76.60.97 – 10.76.60.9810.76.60.99
2610.76.60.100/3010.76.60.101 – 10.76.60.10210.76.60.103
2710.76.60.104/3010.76.60.105 – 10.76.60.10610.76.60.107
2810.76.60.108/3010.76.60.109 – 10.76.60.11010.76.60.111
2910.76.60.112/3010.76.60.113 – 10.76.60.11410.76.60.115
3010.76.60.116/3010.76.60.117 – 10.76.60.11810.76.60.119
3110.76.60.120/3010.76.60.121 – 10.76.60.12210.76.60.123
3210.76.60.124/3010.76.60.125 – 10.76.60.12610.76.60.127
3310.76.60.128/3010.76.60.129 – 10.76.60.13010.76.60.131
3410.76.60.132/3010.76.60.133 – 10.76.60.13410.76.60.135
3510.76.60.136/3010.76.60.137 – 10.76.60.13810.76.60.139
3610.76.60.140/3010.76.60.141 – 10.76.60.14210.76.60.143
3710.76.60.144/3010.76.60.145 – 10.76.60.14610.76.60.147
3810.76.60.148/3010.76.60.149 – 10.76.60.15010.76.60.151
3910.76.60.152/3010.76.60.153 – 10.76.60.15410.76.60.155
4010.76.60.156/3010.76.60.157 – 10.76.60.15810.76.60.159
4110.76.60.160/3010.76.60.161 – 10.76.60.16210.76.60.163
4210.76.60.164/3010.76.60.165 – 10.76.60.16610.76.60.167
4310.76.60.168/3010.76.60.169 – 10.76.60.17010.76.60.171
4410.76.60.172/3010.76.60.173 – 10.76.60.17410.76.60.175
4510.76.60.176/3010.76.60.177 – 10.76.60.17810.76.60.179
4610.76.60.180/3010.76.60.181 – 10.76.60.18210.76.60.183
4710.76.60.184/3010.76.60.185 – 10.76.60.18610.76.60.187
4810.76.60.188/3010.76.60.189 – 10.76.60.19010.76.60.191
4910.76.60.192/3010.76.60.193 – 10.76.60.19410.76.60.195
5010.76.60.196/3010.76.60.197 – 10.76.60.19810.76.60.199
5110.76.60.200/3010.76.60.201 – 10.76.60.20210.76.60.203
5210.76.60.204/3010.76.60.205 – 10.76.60.20610.76.60.207
5310.76.60.208/3010.76.60.209 – 10.76.60.21010.76.60.211
5410.76.60.212/3010.76.60.213 – 10.76.60.21410.76.60.215
5510.76.60.216/3010.76.60.217 – 10.76.60.21810.76.60.219
5610.76.60.220/3010.76.60.221 – 10.76.60.22210.76.60.223
5710.76.60.224/3010.76.60.225 – 10.76.60.22610.76.60.227
5810.76.60.228/3010.76.60.229 – 10.76.60.23010.76.60.231
5910.76.60.232/3010.76.60.233 – 10.76.60.23410.76.60.235
6010.76.60.236/3010.76.60.237 – 10.76.60.23810.76.60.239
6110.76.60.240/3010.76.60.241 – 10.76.60.24210.76.60.243
6210.76.60.244/3010.76.60.245 – 10.76.60.24610.76.60.247
6310.76.60.248/3010.76.60.249 – 10.76.60.25010.76.60.251
6410.76.60.252/3010.76.60.253 – 10.76.60.25410.76.60.255
6510.76.61.0/3010.76.61.1 – 10.76.61.210.76.61.3
6610.76.61.4/3010.76.61.5 – 10.76.61.610.76.61.7
6710.76.61.8/3010.76.61.9 – 10.76.61.1010.76.61.11
6810.76.61.12/3010.76.61.13 – 10.76.61.1410.76.61.15
6910.76.61.16/3010.76.61.17 – 10.76.61.1810.76.61.19
7010.76.61.20/3010.76.61.21 – 10.76.61.2210.76.61.23
7110.76.61.24/3010.76.61.25 – 10.76.61.2610.76.61.27
7210.76.61.28/3010.76.61.29 – 10.76.61.3010.76.61.31
7310.76.61.32/3010.76.61.33 – 10.76.61.3410.76.61.35
7410.76.61.36/3010.76.61.37 – 10.76.61.3810.76.61.39
7510.76.61.40/3010.76.61.41 – 10.76.61.4210.76.61.43
7610.76.61.44/3010.76.61.45 – 10.76.61.4610.76.61.47
7710.76.61.48/3010.76.61.49 – 10.76.61.5010.76.61.51
7810.76.61.52/3010.76.61.53 – 10.76.61.5410.76.61.55
7910.76.61.56/3010.76.61.57 – 10.76.61.5810.76.61.59
8010.76.61.60/3010.76.61.61 – 10.76.61.6210.76.61.63
8110.76.61.64/3010.76.61.65 – 10.76.61.6610.76.61.67
8210.76.61.68/3010.76.61.69 – 10.76.61.7010.76.61.71
8310.76.61.72/3010.76.61.73 – 10.76.61.7410.76.61.75
8410.76.61.76/3010.76.61.77 – 10.76.61.7810.76.61.79
8510.76.61.80/3010.76.61.81 – 10.76.61.8210.76.61.83
8610.76.61.84/3010.76.61.85 – 10.76.61.8610.76.61.87
8710.76.61.88/3010.76.61.89 – 10.76.61.9010.76.61.91
8810.76.61.92/3010.76.61.93 – 10.76.61.9410.76.61.95
8910.76.61.96/3010.76.61.97 – 10.76.61.9810.76.61.99
9010.76.61.100/3010.76.61.101 – 10.76.61.10210.76.61.103
9110.76.61.104/3010.76.61.105 – 10.76.61.10610.76.61.107
9210.76.61.108/3010.76.61.109 – 10.76.61.11010.76.61.111
9310.76.61.112/3010.76.61.113 – 10.76.61.11410.76.61.115
9410.76.61.116/3010.76.61.117 – 10.76.61.11810.76.61.119
9510.76.61.120/3010.76.61.121 – 10.76.61.12210.76.61.123
9610.76.61.124/3010.76.61.125 – 10.76.61.12610.76.61.127
9710.76.61.128/3010.76.61.129 – 10.76.61.13010.76.61.131
9810.76.61.132/3010.76.61.133 – 10.76.61.13410.76.61.135
9910.76.61.136/3010.76.61.137 – 10.76.61.13810.76.61.139
10010.76.61.140/3010.76.61.141 – 10.76.61.14210.76.61.143
10110.76.61.144/3010.76.61.145 – 10.76.61.14610.76.61.147
10210.76.61.148/3010.76.61.149 – 10.76.61.15010.76.61.151
10310.76.61.152/3010.76.61.153 – 10.76.61.15410.76.61.155
10410.76.61.156/3010.76.61.157 – 10.76.61.15810.76.61.159
10510.76.61.160/3010.76.61.161 – 10.76.61.16210.76.61.163
10610.76.61.164/3010.76.61.165 – 10.76.61.16610.76.61.167
10710.76.61.168/3010.76.61.169 – 10.76.61.17010.76.61.171
10810.76.61.172/3010.76.61.173 – 10.76.61.17410.76.61.175
10910.76.61.176/3010.76.61.177 – 10.76.61.17810.76.61.179
11010.76.61.180/3010.76.61.181 – 10.76.61.18210.76.61.183
11110.76.61.184/3010.76.61.185 – 10.76.61.18610.76.61.187
11210.76.61.188/3010.76.61.189 – 10.76.61.19010.76.61.191
11310.76.61.192/3010.76.61.193 – 10.76.61.19410.76.61.195
11410.76.61.196/3010.76.61.197 – 10.76.61.19810.76.61.199
11510.76.61.200/3010.76.61.201 – 10.76.61.20210.76.61.203
11610.76.61.204/3010.76.61.205 – 10.76.61.20610.76.61.207
11710.76.61.208/3010.76.61.209 – 10.76.61.21010.76.61.211
11810.76.61.212/3010.76.61.213 – 10.76.61.21410.76.61.215
11910.76.61.216/3010.76.61.217 – 10.76.61.21810.76.61.219
12010.76.61.220/3010.76.61.221 – 10.76.61.22210.76.61.223
12110.76.61.224/3010.76.61.225 – 10.76.61.22610.76.61.227
12210.76.61.228/3010.76.61.229 – 10.76.61.23010.76.61.231
12310.76.61.232/3010.76.61.233 – 10.76.61.23410.76.61.235
12410.76.61.236/3010.76.61.237 – 10.76.61.23810.76.61.239
12510.76.61.240/3010.76.61.241 – 10.76.61.24210.76.61.243
12610.76.61.244/3010.76.61.245 – 10.76.61.24610.76.61.247
12710.76.61.248/3010.76.61.249 – 10.76.61.25010.76.61.251
12810.76.61.252/3010.76.61.253 – 10.76.61.25410.76.61.255
12910.76.62.0/3010.76.62.1 – 10.76.62.210.76.62.3
13010.76.62.4/3010.76.62.5 – 10.76.62.610.76.62.7
13110.76.62.8/3010.76.62.9 – 10.76.62.1010.76.62.11
13210.76.62.12/3010.76.62.13 – 10.76.62.1410.76.62.15
13310.76.62.16/3010.76.62.17 – 10.76.62.1810.76.62.19
13410.76.62.20/3010.76.62.21 – 10.76.62.2210.76.62.23
13510.76.62.24/3010.76.62.25 – 10.76.62.2610.76.62.27
13610.76.62.28/3010.76.62.29 – 10.76.62.3010.76.62.31
13710.76.62.32/3010.76.62.33 – 10.76.62.3410.76.62.35
13810.76.62.36/3010.76.62.37 – 10.76.62.3810.76.62.39
13910.76.62.40/3010.76.62.41 – 10.76.62.4210.76.62.43
14010.76.62.44/3010.76.62.45 – 10.76.62.4610.76.62.47
14110.76.62.48/3010.76.62.49 – 10.76.62.5010.76.62.51
14210.76.62.52/3010.76.62.53 – 10.76.62.5410.76.62.55
14310.76.62.56/3010.76.62.57 – 10.76.62.5810.76.62.59
14410.76.62.60/3010.76.62.61 – 10.76.62.6210.76.62.63
14510.76.62.64/3010.76.62.65 – 10.76.62.6610.76.62.67
14610.76.62.68/3010.76.62.69 – 10.76.62.7010.76.62.71
14710.76.62.72/3010.76.62.73 – 10.76.62.7410.76.62.75
14810.76.62.76/3010.76.62.77 – 10.76.62.7810.76.62.79
14910.76.62.80/3010.76.62.81 – 10.76.62.8210.76.62.83
15010.76.62.84/3010.76.62.85 – 10.76.62.8610.76.62.87
15110.76.62.88/3010.76.62.89 – 10.76.62.9010.76.62.91
15210.76.62.92/3010.76.62.93 – 10.76.62.9410.76.62.95
15310.76.62.96/3010.76.62.97 – 10.76.62.9810.76.62.99
15410.76.62.100/3010.76.62.101 – 10.76.62.10210.76.62.103
15510.76.62.104/3010.76.62.105 – 10.76.62.10610.76.62.107
15610.76.62.108/3010.76.62.109 – 10.76.62.11010.76.62.111
15710.76.62.112/3010.76.62.113 – 10.76.62.11410.76.62.115
15810.76.62.116/3010.76.62.117 – 10.76.62.11810.76.62.119
15910.76.62.120/3010.76.62.121 – 10.76.62.12210.76.62.123
16010.76.62.124/3010.76.62.125 – 10.76.62.12610.76.62.127
16110.76.62.128/3010.76.62.129 – 10.76.62.13010.76.62.131
16210.76.62.132/3010.76.62.133 – 10.76.62.13410.76.62.135
16310.76.62.136/3010.76.62.137 – 10.76.62.13810.76.62.139
16410.76.62.140/3010.76.62.141 – 10.76.62.14210.76.62.143
16510.76.62.144/3010.76.62.145 – 10.76.62.14610.76.62.147
16610.76.62.148/3010.76.62.149 – 10.76.62.15010.76.62.151
16710.76.62.152/3010.76.62.153 – 10.76.62.15410.76.62.155
16810.76.62.156/3010.76.62.157 – 10.76.62.15810.76.62.159
16910.76.62.160/3010.76.62.161 – 10.76.62.16210.76.62.163
17010.76.62.164/3010.76.62.165 – 10.76.62.16610.76.62.167
17110.76.62.168/3010.76.62.169 – 10.76.62.17010.76.62.171
17210.76.62.172/3010.76.62.173 – 10.76.62.17410.76.62.175
17310.76.62.176/3010.76.62.177 – 10.76.62.17810.76.62.179
17410.76.62.180/3010.76.62.181 – 10.76.62.18210.76.62.183
17510.76.62.184/3010.76.62.185 – 10.76.62.18610.76.62.187
17610.76.62.188/3010.76.62.189 – 10.76.62.19010.76.62.191
17710.76.62.192/3010.76.62.193 – 10.76.62.19410.76.62.195
17810.76.62.196/3010.76.62.197 – 10.76.62.19810.76.62.199
17910.76.62.200/3010.76.62.201 – 10.76.62.20210.76.62.203
18010.76.62.204/3010.76.62.205 – 10.76.62.20610.76.62.207
18110.76.62.208/3010.76.62.209 – 10.76.62.21010.76.62.211
18210.76.62.212/3010.76.62.213 – 10.76.62.21410.76.62.215
18310.76.62.216/3010.76.62.217 – 10.76.62.21810.76.62.219
18410.76.62.220/3010.76.62.221 – 10.76.62.22210.76.62.223
18510.76.62.224/3010.76.62.225 – 10.76.62.22610.76.62.227
18610.76.62.228/3010.76.62.229 – 10.76.62.23010.76.62.231
18710.76.62.232/3010.76.62.233 – 10.76.62.23410.76.62.235
18810.76.62.236/3010.76.62.237 – 10.76.62.23810.76.62.239
18910.76.62.240/3010.76.62.241 – 10.76.62.24210.76.62.243
19010.76.62.244/3010.76.62.245 – 10.76.62.24610.76.62.247
19110.76.62.248/3010.76.62.249 – 10.76.62.25010.76.62.251
19210.76.62.252/3010.76.62.253 – 10.76.62.25410.76.62.255
19310.76.63.0/3010.76.63.1 – 10.76.63.210.76.63.3
19410.76.63.4/3010.76.63.5 – 10.76.63.610.76.63.7
19510.76.63.8/3010.76.63.9 – 10.76.63.1010.76.63.11
19610.76.63.12/3010.76.63.13 – 10.76.63.1410.76.63.15
19710.76.63.16/3010.76.63.17 – 10.76.63.1810.76.63.19
19810.76.63.20/3010.76.63.21 – 10.76.63.2210.76.63.23
19910.76.63.24/3010.76.63.25 – 10.76.63.2610.76.63.27
20010.76.63.28/3010.76.63.29 – 10.76.63.3010.76.63.31
20110.76.63.32/3010.76.63.33 – 10.76.63.3410.76.63.35
20210.76.63.36/3010.76.63.37 – 10.76.63.3810.76.63.39
20310.76.63.40/3010.76.63.41 – 10.76.63.4210.76.63.43
20410.76.63.44/3010.76.63.45 – 10.76.63.4610.76.63.47
20510.76.63.48/3010.76.63.49 – 10.76.63.5010.76.63.51
20610.76.63.52/3010.76.63.53 – 10.76.63.5410.76.63.55
20710.76.63.56/3010.76.63.57 – 10.76.63.5810.76.63.59
20810.76.63.60/3010.76.63.61 – 10.76.63.6210.76.63.63
20910.76.63.64/3010.76.63.65 – 10.76.63.6610.76.63.67
21010.76.63.68/3010.76.63.69 – 10.76.63.7010.76.63.71
21110.76.63.72/3010.76.63.73 – 10.76.63.7410.76.63.75
21210.76.63.76/3010.76.63.77 – 10.76.63.7810.76.63.79
21310.76.63.80/3010.76.63.81 – 10.76.63.8210.76.63.83
21410.76.63.84/3010.76.63.85 – 10.76.63.8610.76.63.87
21510.76.63.88/3010.76.63.89 – 10.76.63.9010.76.63.91
21610.76.63.92/3010.76.63.93 – 10.76.63.9410.76.63.95
21710.76.63.96/3010.76.63.97 – 10.76.63.9810.76.63.99
21810.76.63.100/3010.76.63.101 – 10.76.63.10210.76.63.103
21910.76.63.104/3010.76.63.105 – 10.76.63.10610.76.63.107
22010.76.63.108/3010.76.63.109 – 10.76.63.11010.76.63.111
22110.76.63.112/3010.76.63.113 – 10.76.63.11410.76.63.115
22210.76.63.116/3010.76.63.117 – 10.76.63.11810.76.63.119
22310.76.63.120/3010.76.63.121 – 10.76.63.12210.76.63.123
22410.76.63.124/3010.76.63.125 – 10.76.63.12610.76.63.127
22510.76.63.128/3010.76.63.129 – 10.76.63.13010.76.63.131
22610.76.63.132/3010.76.63.133 – 10.76.63.13410.76.63.135
22710.76.63.136/3010.76.63.137 – 10.76.63.13810.76.63.139
22810.76.63.140/3010.76.63.141 – 10.76.63.14210.76.63.143
22910.76.63.144/3010.76.63.145 – 10.76.63.14610.76.63.147
23010.76.63.148/3010.76.63.149 – 10.76.63.15010.76.63.151
23110.76.63.152/3010.76.63.153 – 10.76.63.15410.76.63.155
23210.76.63.156/3010.76.63.157 – 10.76.63.15810.76.63.159
23310.76.63.160/3010.76.63.161 – 10.76.63.16210.76.63.163
23410.76.63.164/3010.76.63.165 – 10.76.63.16610.76.63.167
23510.76.63.168/3010.76.63.169 – 10.76.63.17010.76.63.171
23610.76.63.172/3010.76.63.173 – 10.76.63.17410.76.63.175
23710.76.63.176/3010.76.63.177 – 10.76.63.17810.76.63.179
23810.76.63.180/3010.76.63.181 – 10.76.63.18210.76.63.183
23910.76.63.184/3010.76.63.185 – 10.76.63.18610.76.63.187
24010.76.63.188/3010.76.63.189 – 10.76.63.19010.76.63.191
24110.76.63.192/3010.76.63.193 – 10.76.63.19410.76.63.195
24210.76.63.196/3010.76.63.197 – 10.76.63.19810.76.63.199
24310.76.63.200/3010.76.63.201 – 10.76.63.20210.76.63.203
24410.76.63.204/3010.76.63.205 – 10.76.63.20610.76.63.207
24510.76.63.208/3010.76.63.209 – 10.76.63.21010.76.63.211
24610.76.63.212/3010.76.63.213 – 10.76.63.21410.76.63.215
24710.76.63.216/3010.76.63.217 – 10.76.63.21810.76.63.219
24810.76.63.220/3010.76.63.221 – 10.76.63.22210.76.63.223
24910.76.63.224/3010.76.63.225 – 10.76.63.22610.76.63.227
25010.76.63.228/3010.76.63.229 – 10.76.63.23010.76.63.231
25110.76.63.232/3010.76.63.233 – 10.76.63.23410.76.63.235
25210.76.63.236/3010.76.63.237 – 10.76.63.23810.76.63.239
25310.76.63.240/3010.76.63.241 – 10.76.63.24210.76.63.243
25410.76.63.244/3010.76.63.245 – 10.76.63.24610.76.63.247
25510.76.63.248/3010.76.63.249 – 10.76.63.25010.76.63.251
25610.76.63.252/3010.76.63.253 – 10.76.63.25410.76.63.255
01 / table

IPv4 CIDR prefix table.

Click a prefix longer than your network to split it into subnets.

prefixsubnet maskaddresseshostsin your /22
/00.0.0.04,294,967,2964,294,967,294-
/1128.0.0.02,147,483,6482,147,483,646-
/2192.0.0.01,073,741,8241,073,741,822-
/3224.0.0.0536,870,912536,870,910-
/4240.0.0.0268,435,456268,435,454-
/5248.0.0.0134,217,728134,217,726-
/6252.0.0.067,108,86467,108,862-
/7254.0.0.033,554,43233,554,430-
/8255.0.0.016,777,21616,777,214-
/9255.128.0.08,388,6088,388,606-
/10255.192.0.04,194,3044,194,302-
/11255.224.0.02,097,1522,097,150-
/12255.240.0.01,048,5761,048,574-
/13255.248.0.0524,288524,286-
/14255.252.0.0262,144262,142-
/15255.254.0.0131,072131,070-
/16255.255.0.065,53665,534-
/17255.255.128.032,76832,766-
/18255.255.192.016,38416,382-
/19255.255.224.08,1928,190-
/20255.255.240.04,0964,094-
/21255.255.248.02,0482,046-
/22255.255.252.01,0241,0221
/23255.255.254.05125102 split →
/24255.255.255.02562544 split →
/25255.255.255.1281281268 split →
/26255.255.255.192646216 split →
/27255.255.255.224323032 split →
/28255.255.255.240161464 split →
/29255.255.255.24886128 split →
/30255.255.255.25242256 split →
/31255.255.255.25422512 split →
/32255.255.255.255111,024 split →
02 / faq

About this calculator.

How do I use this subnet calculator?

▼

Type an IP address followed by a prefix, like 192.168.1.10/24, or by a subnet mask, like 192.168.1.10 255.255.255.0. Without a prefix it uses /24. Click a row in the table to split the network into smaller subnets.

Why are usable hosts always 2 fewer?

▼

The first address in a subnet is the network address and the last is the broadcast address, so neither can go to a device. The exceptions are /31 (point-to-point links, RFC 3021) and /32 (a single address), which use every address.

Can I use it from a terminal?

▼

Yes. curl 'ipku.in/en/tools/ipv4-subnet-calculator?q=192.168.1.10/24' returns the result as plain text.

Learn how to work it out →