IPv4 Subnet Calculator

Enter an IP with a CIDR prefix or a subnet mask to see its network, broadcast, host range, and host count. You can also split the network into smaller subnets.

$ ipcalc
private IP (RFC 1918)10.75.0.0/16
network10.75.0.0/16
broadcast10.75.255.255
first host10.75.0.1
last host10.75.255.254
subnet mask255.255.0.0
wildcard0.0.255.255
addresses65,536
usable hosts65,534
classA
ipcalc 10.75.0.0/16
address00001010.01001011.00000000.00000000
subnet mask11111111.11111111.00000000.00000000
network00001010.01001011.00000000.00000000
broadcast00001010.01001011.11111111.11111111
green = network part, grey = host part
hex0x0a4b0000
decimal172687360
reverse dns0.0.75.10.in-addr.arpa
ipv4-mapped::ffff:a4b:0

/16 split into /24 · 256 subnets

close ×
#networkhost rangebroadcast
110.75.0.0/2410.75.0.1 – 10.75.0.25410.75.0.255
210.75.1.0/2410.75.1.1 – 10.75.1.25410.75.1.255
310.75.2.0/2410.75.2.1 – 10.75.2.25410.75.2.255
410.75.3.0/2410.75.3.1 – 10.75.3.25410.75.3.255
510.75.4.0/2410.75.4.1 – 10.75.4.25410.75.4.255
610.75.5.0/2410.75.5.1 – 10.75.5.25410.75.5.255
710.75.6.0/2410.75.6.1 – 10.75.6.25410.75.6.255
810.75.7.0/2410.75.7.1 – 10.75.7.25410.75.7.255
910.75.8.0/2410.75.8.1 – 10.75.8.25410.75.8.255
1010.75.9.0/2410.75.9.1 – 10.75.9.25410.75.9.255
1110.75.10.0/2410.75.10.1 – 10.75.10.25410.75.10.255
1210.75.11.0/2410.75.11.1 – 10.75.11.25410.75.11.255
1310.75.12.0/2410.75.12.1 – 10.75.12.25410.75.12.255
1410.75.13.0/2410.75.13.1 – 10.75.13.25410.75.13.255
1510.75.14.0/2410.75.14.1 – 10.75.14.25410.75.14.255
1610.75.15.0/2410.75.15.1 – 10.75.15.25410.75.15.255
1710.75.16.0/2410.75.16.1 – 10.75.16.25410.75.16.255
1810.75.17.0/2410.75.17.1 – 10.75.17.25410.75.17.255
1910.75.18.0/2410.75.18.1 – 10.75.18.25410.75.18.255
2010.75.19.0/2410.75.19.1 – 10.75.19.25410.75.19.255
2110.75.20.0/2410.75.20.1 – 10.75.20.25410.75.20.255
2210.75.21.0/2410.75.21.1 – 10.75.21.25410.75.21.255
2310.75.22.0/2410.75.22.1 – 10.75.22.25410.75.22.255
2410.75.23.0/2410.75.23.1 – 10.75.23.25410.75.23.255
2510.75.24.0/2410.75.24.1 – 10.75.24.25410.75.24.255
2610.75.25.0/2410.75.25.1 – 10.75.25.25410.75.25.255
2710.75.26.0/2410.75.26.1 – 10.75.26.25410.75.26.255
2810.75.27.0/2410.75.27.1 – 10.75.27.25410.75.27.255
2910.75.28.0/2410.75.28.1 – 10.75.28.25410.75.28.255
3010.75.29.0/2410.75.29.1 – 10.75.29.25410.75.29.255
3110.75.30.0/2410.75.30.1 – 10.75.30.25410.75.30.255
3210.75.31.0/2410.75.31.1 – 10.75.31.25410.75.31.255
3310.75.32.0/2410.75.32.1 – 10.75.32.25410.75.32.255
3410.75.33.0/2410.75.33.1 – 10.75.33.25410.75.33.255
3510.75.34.0/2410.75.34.1 – 10.75.34.25410.75.34.255
3610.75.35.0/2410.75.35.1 – 10.75.35.25410.75.35.255
3710.75.36.0/2410.75.36.1 – 10.75.36.25410.75.36.255
3810.75.37.0/2410.75.37.1 – 10.75.37.25410.75.37.255
3910.75.38.0/2410.75.38.1 – 10.75.38.25410.75.38.255
4010.75.39.0/2410.75.39.1 – 10.75.39.25410.75.39.255
4110.75.40.0/2410.75.40.1 – 10.75.40.25410.75.40.255
4210.75.41.0/2410.75.41.1 – 10.75.41.25410.75.41.255
4310.75.42.0/2410.75.42.1 – 10.75.42.25410.75.42.255
4410.75.43.0/2410.75.43.1 – 10.75.43.25410.75.43.255
4510.75.44.0/2410.75.44.1 – 10.75.44.25410.75.44.255
4610.75.45.0/2410.75.45.1 – 10.75.45.25410.75.45.255
4710.75.46.0/2410.75.46.1 – 10.75.46.25410.75.46.255
4810.75.47.0/2410.75.47.1 – 10.75.47.25410.75.47.255
4910.75.48.0/2410.75.48.1 – 10.75.48.25410.75.48.255
5010.75.49.0/2410.75.49.1 – 10.75.49.25410.75.49.255
5110.75.50.0/2410.75.50.1 – 10.75.50.25410.75.50.255
5210.75.51.0/2410.75.51.1 – 10.75.51.25410.75.51.255
5310.75.52.0/2410.75.52.1 – 10.75.52.25410.75.52.255
5410.75.53.0/2410.75.53.1 – 10.75.53.25410.75.53.255
5510.75.54.0/2410.75.54.1 – 10.75.54.25410.75.54.255
5610.75.55.0/2410.75.55.1 – 10.75.55.25410.75.55.255
5710.75.56.0/2410.75.56.1 – 10.75.56.25410.75.56.255
5810.75.57.0/2410.75.57.1 – 10.75.57.25410.75.57.255
5910.75.58.0/2410.75.58.1 – 10.75.58.25410.75.58.255
6010.75.59.0/2410.75.59.1 – 10.75.59.25410.75.59.255
6110.75.60.0/2410.75.60.1 – 10.75.60.25410.75.60.255
6210.75.61.0/2410.75.61.1 – 10.75.61.25410.75.61.255
6310.75.62.0/2410.75.62.1 – 10.75.62.25410.75.62.255
6410.75.63.0/2410.75.63.1 – 10.75.63.25410.75.63.255
6510.75.64.0/2410.75.64.1 – 10.75.64.25410.75.64.255
6610.75.65.0/2410.75.65.1 – 10.75.65.25410.75.65.255
6710.75.66.0/2410.75.66.1 – 10.75.66.25410.75.66.255
6810.75.67.0/2410.75.67.1 – 10.75.67.25410.75.67.255
6910.75.68.0/2410.75.68.1 – 10.75.68.25410.75.68.255
7010.75.69.0/2410.75.69.1 – 10.75.69.25410.75.69.255
7110.75.70.0/2410.75.70.1 – 10.75.70.25410.75.70.255
7210.75.71.0/2410.75.71.1 – 10.75.71.25410.75.71.255
7310.75.72.0/2410.75.72.1 – 10.75.72.25410.75.72.255
7410.75.73.0/2410.75.73.1 – 10.75.73.25410.75.73.255
7510.75.74.0/2410.75.74.1 – 10.75.74.25410.75.74.255
7610.75.75.0/2410.75.75.1 – 10.75.75.25410.75.75.255
7710.75.76.0/2410.75.76.1 – 10.75.76.25410.75.76.255
7810.75.77.0/2410.75.77.1 – 10.75.77.25410.75.77.255
7910.75.78.0/2410.75.78.1 – 10.75.78.25410.75.78.255
8010.75.79.0/2410.75.79.1 – 10.75.79.25410.75.79.255
8110.75.80.0/2410.75.80.1 – 10.75.80.25410.75.80.255
8210.75.81.0/2410.75.81.1 – 10.75.81.25410.75.81.255
8310.75.82.0/2410.75.82.1 – 10.75.82.25410.75.82.255
8410.75.83.0/2410.75.83.1 – 10.75.83.25410.75.83.255
8510.75.84.0/2410.75.84.1 – 10.75.84.25410.75.84.255
8610.75.85.0/2410.75.85.1 – 10.75.85.25410.75.85.255
8710.75.86.0/2410.75.86.1 – 10.75.86.25410.75.86.255
8810.75.87.0/2410.75.87.1 – 10.75.87.25410.75.87.255
8910.75.88.0/2410.75.88.1 – 10.75.88.25410.75.88.255
9010.75.89.0/2410.75.89.1 – 10.75.89.25410.75.89.255
9110.75.90.0/2410.75.90.1 – 10.75.90.25410.75.90.255
9210.75.91.0/2410.75.91.1 – 10.75.91.25410.75.91.255
9310.75.92.0/2410.75.92.1 – 10.75.92.25410.75.92.255
9410.75.93.0/2410.75.93.1 – 10.75.93.25410.75.93.255
9510.75.94.0/2410.75.94.1 – 10.75.94.25410.75.94.255
9610.75.95.0/2410.75.95.1 – 10.75.95.25410.75.95.255
9710.75.96.0/2410.75.96.1 – 10.75.96.25410.75.96.255
9810.75.97.0/2410.75.97.1 – 10.75.97.25410.75.97.255
9910.75.98.0/2410.75.98.1 – 10.75.98.25410.75.98.255
10010.75.99.0/2410.75.99.1 – 10.75.99.25410.75.99.255
10110.75.100.0/2410.75.100.1 – 10.75.100.25410.75.100.255
10210.75.101.0/2410.75.101.1 – 10.75.101.25410.75.101.255
10310.75.102.0/2410.75.102.1 – 10.75.102.25410.75.102.255
10410.75.103.0/2410.75.103.1 – 10.75.103.25410.75.103.255
10510.75.104.0/2410.75.104.1 – 10.75.104.25410.75.104.255
10610.75.105.0/2410.75.105.1 – 10.75.105.25410.75.105.255
10710.75.106.0/2410.75.106.1 – 10.75.106.25410.75.106.255
10810.75.107.0/2410.75.107.1 – 10.75.107.25410.75.107.255
10910.75.108.0/2410.75.108.1 – 10.75.108.25410.75.108.255
11010.75.109.0/2410.75.109.1 – 10.75.109.25410.75.109.255
11110.75.110.0/2410.75.110.1 – 10.75.110.25410.75.110.255
11210.75.111.0/2410.75.111.1 – 10.75.111.25410.75.111.255
11310.75.112.0/2410.75.112.1 – 10.75.112.25410.75.112.255
11410.75.113.0/2410.75.113.1 – 10.75.113.25410.75.113.255
11510.75.114.0/2410.75.114.1 – 10.75.114.25410.75.114.255
11610.75.115.0/2410.75.115.1 – 10.75.115.25410.75.115.255
11710.75.116.0/2410.75.116.1 – 10.75.116.25410.75.116.255
11810.75.117.0/2410.75.117.1 – 10.75.117.25410.75.117.255
11910.75.118.0/2410.75.118.1 – 10.75.118.25410.75.118.255
12010.75.119.0/2410.75.119.1 – 10.75.119.25410.75.119.255
12110.75.120.0/2410.75.120.1 – 10.75.120.25410.75.120.255
12210.75.121.0/2410.75.121.1 – 10.75.121.25410.75.121.255
12310.75.122.0/2410.75.122.1 – 10.75.122.25410.75.122.255
12410.75.123.0/2410.75.123.1 – 10.75.123.25410.75.123.255
12510.75.124.0/2410.75.124.1 – 10.75.124.25410.75.124.255
12610.75.125.0/2410.75.125.1 – 10.75.125.25410.75.125.255
12710.75.126.0/2410.75.126.1 – 10.75.126.25410.75.126.255
12810.75.127.0/2410.75.127.1 – 10.75.127.25410.75.127.255
12910.75.128.0/2410.75.128.1 – 10.75.128.25410.75.128.255
13010.75.129.0/2410.75.129.1 – 10.75.129.25410.75.129.255
13110.75.130.0/2410.75.130.1 – 10.75.130.25410.75.130.255
13210.75.131.0/2410.75.131.1 – 10.75.131.25410.75.131.255
13310.75.132.0/2410.75.132.1 – 10.75.132.25410.75.132.255
13410.75.133.0/2410.75.133.1 – 10.75.133.25410.75.133.255
13510.75.134.0/2410.75.134.1 – 10.75.134.25410.75.134.255
13610.75.135.0/2410.75.135.1 – 10.75.135.25410.75.135.255
13710.75.136.0/2410.75.136.1 – 10.75.136.25410.75.136.255
13810.75.137.0/2410.75.137.1 – 10.75.137.25410.75.137.255
13910.75.138.0/2410.75.138.1 – 10.75.138.25410.75.138.255
14010.75.139.0/2410.75.139.1 – 10.75.139.25410.75.139.255
14110.75.140.0/2410.75.140.1 – 10.75.140.25410.75.140.255
14210.75.141.0/2410.75.141.1 – 10.75.141.25410.75.141.255
14310.75.142.0/2410.75.142.1 – 10.75.142.25410.75.142.255
14410.75.143.0/2410.75.143.1 – 10.75.143.25410.75.143.255
14510.75.144.0/2410.75.144.1 – 10.75.144.25410.75.144.255
14610.75.145.0/2410.75.145.1 – 10.75.145.25410.75.145.255
14710.75.146.0/2410.75.146.1 – 10.75.146.25410.75.146.255
14810.75.147.0/2410.75.147.1 – 10.75.147.25410.75.147.255
14910.75.148.0/2410.75.148.1 – 10.75.148.25410.75.148.255
15010.75.149.0/2410.75.149.1 – 10.75.149.25410.75.149.255
15110.75.150.0/2410.75.150.1 – 10.75.150.25410.75.150.255
15210.75.151.0/2410.75.151.1 – 10.75.151.25410.75.151.255
15310.75.152.0/2410.75.152.1 – 10.75.152.25410.75.152.255
15410.75.153.0/2410.75.153.1 – 10.75.153.25410.75.153.255
15510.75.154.0/2410.75.154.1 – 10.75.154.25410.75.154.255
15610.75.155.0/2410.75.155.1 – 10.75.155.25410.75.155.255
15710.75.156.0/2410.75.156.1 – 10.75.156.25410.75.156.255
15810.75.157.0/2410.75.157.1 – 10.75.157.25410.75.157.255
15910.75.158.0/2410.75.158.1 – 10.75.158.25410.75.158.255
16010.75.159.0/2410.75.159.1 – 10.75.159.25410.75.159.255
16110.75.160.0/2410.75.160.1 – 10.75.160.25410.75.160.255
16210.75.161.0/2410.75.161.1 – 10.75.161.25410.75.161.255
16310.75.162.0/2410.75.162.1 – 10.75.162.25410.75.162.255
16410.75.163.0/2410.75.163.1 – 10.75.163.25410.75.163.255
16510.75.164.0/2410.75.164.1 – 10.75.164.25410.75.164.255
16610.75.165.0/2410.75.165.1 – 10.75.165.25410.75.165.255
16710.75.166.0/2410.75.166.1 – 10.75.166.25410.75.166.255
16810.75.167.0/2410.75.167.1 – 10.75.167.25410.75.167.255
16910.75.168.0/2410.75.168.1 – 10.75.168.25410.75.168.255
17010.75.169.0/2410.75.169.1 – 10.75.169.25410.75.169.255
17110.75.170.0/2410.75.170.1 – 10.75.170.25410.75.170.255
17210.75.171.0/2410.75.171.1 – 10.75.171.25410.75.171.255
17310.75.172.0/2410.75.172.1 – 10.75.172.25410.75.172.255
17410.75.173.0/2410.75.173.1 – 10.75.173.25410.75.173.255
17510.75.174.0/2410.75.174.1 – 10.75.174.25410.75.174.255
17610.75.175.0/2410.75.175.1 – 10.75.175.25410.75.175.255
17710.75.176.0/2410.75.176.1 – 10.75.176.25410.75.176.255
17810.75.177.0/2410.75.177.1 – 10.75.177.25410.75.177.255
17910.75.178.0/2410.75.178.1 – 10.75.178.25410.75.178.255
18010.75.179.0/2410.75.179.1 – 10.75.179.25410.75.179.255
18110.75.180.0/2410.75.180.1 – 10.75.180.25410.75.180.255
18210.75.181.0/2410.75.181.1 – 10.75.181.25410.75.181.255
18310.75.182.0/2410.75.182.1 – 10.75.182.25410.75.182.255
18410.75.183.0/2410.75.183.1 – 10.75.183.25410.75.183.255
18510.75.184.0/2410.75.184.1 – 10.75.184.25410.75.184.255
18610.75.185.0/2410.75.185.1 – 10.75.185.25410.75.185.255
18710.75.186.0/2410.75.186.1 – 10.75.186.25410.75.186.255
18810.75.187.0/2410.75.187.1 – 10.75.187.25410.75.187.255
18910.75.188.0/2410.75.188.1 – 10.75.188.25410.75.188.255
19010.75.189.0/2410.75.189.1 – 10.75.189.25410.75.189.255
19110.75.190.0/2410.75.190.1 – 10.75.190.25410.75.190.255
19210.75.191.0/2410.75.191.1 – 10.75.191.25410.75.191.255
19310.75.192.0/2410.75.192.1 – 10.75.192.25410.75.192.255
19410.75.193.0/2410.75.193.1 – 10.75.193.25410.75.193.255
19510.75.194.0/2410.75.194.1 – 10.75.194.25410.75.194.255
19610.75.195.0/2410.75.195.1 – 10.75.195.25410.75.195.255
19710.75.196.0/2410.75.196.1 – 10.75.196.25410.75.196.255
19810.75.197.0/2410.75.197.1 – 10.75.197.25410.75.197.255
19910.75.198.0/2410.75.198.1 – 10.75.198.25410.75.198.255
20010.75.199.0/2410.75.199.1 – 10.75.199.25410.75.199.255
20110.75.200.0/2410.75.200.1 – 10.75.200.25410.75.200.255
20210.75.201.0/2410.75.201.1 – 10.75.201.25410.75.201.255
20310.75.202.0/2410.75.202.1 – 10.75.202.25410.75.202.255
20410.75.203.0/2410.75.203.1 – 10.75.203.25410.75.203.255
20510.75.204.0/2410.75.204.1 – 10.75.204.25410.75.204.255
20610.75.205.0/2410.75.205.1 – 10.75.205.25410.75.205.255
20710.75.206.0/2410.75.206.1 – 10.75.206.25410.75.206.255
20810.75.207.0/2410.75.207.1 – 10.75.207.25410.75.207.255
20910.75.208.0/2410.75.208.1 – 10.75.208.25410.75.208.255
21010.75.209.0/2410.75.209.1 – 10.75.209.25410.75.209.255
21110.75.210.0/2410.75.210.1 – 10.75.210.25410.75.210.255
21210.75.211.0/2410.75.211.1 – 10.75.211.25410.75.211.255
21310.75.212.0/2410.75.212.1 – 10.75.212.25410.75.212.255
21410.75.213.0/2410.75.213.1 – 10.75.213.25410.75.213.255
21510.75.214.0/2410.75.214.1 – 10.75.214.25410.75.214.255
21610.75.215.0/2410.75.215.1 – 10.75.215.25410.75.215.255
21710.75.216.0/2410.75.216.1 – 10.75.216.25410.75.216.255
21810.75.217.0/2410.75.217.1 – 10.75.217.25410.75.217.255
21910.75.218.0/2410.75.218.1 – 10.75.218.25410.75.218.255
22010.75.219.0/2410.75.219.1 – 10.75.219.25410.75.219.255
22110.75.220.0/2410.75.220.1 – 10.75.220.25410.75.220.255
22210.75.221.0/2410.75.221.1 – 10.75.221.25410.75.221.255
22310.75.222.0/2410.75.222.1 – 10.75.222.25410.75.222.255
22410.75.223.0/2410.75.223.1 – 10.75.223.25410.75.223.255
22510.75.224.0/2410.75.224.1 – 10.75.224.25410.75.224.255
22610.75.225.0/2410.75.225.1 – 10.75.225.25410.75.225.255
22710.75.226.0/2410.75.226.1 – 10.75.226.25410.75.226.255
22810.75.227.0/2410.75.227.1 – 10.75.227.25410.75.227.255
22910.75.228.0/2410.75.228.1 – 10.75.228.25410.75.228.255
23010.75.229.0/2410.75.229.1 – 10.75.229.25410.75.229.255
23110.75.230.0/2410.75.230.1 – 10.75.230.25410.75.230.255
23210.75.231.0/2410.75.231.1 – 10.75.231.25410.75.231.255
23310.75.232.0/2410.75.232.1 – 10.75.232.25410.75.232.255
23410.75.233.0/2410.75.233.1 – 10.75.233.25410.75.233.255
23510.75.234.0/2410.75.234.1 – 10.75.234.25410.75.234.255
23610.75.235.0/2410.75.235.1 – 10.75.235.25410.75.235.255
23710.75.236.0/2410.75.236.1 – 10.75.236.25410.75.236.255
23810.75.237.0/2410.75.237.1 – 10.75.237.25410.75.237.255
23910.75.238.0/2410.75.238.1 – 10.75.238.25410.75.238.255
24010.75.239.0/2410.75.239.1 – 10.75.239.25410.75.239.255
24110.75.240.0/2410.75.240.1 – 10.75.240.25410.75.240.255
24210.75.241.0/2410.75.241.1 – 10.75.241.25410.75.241.255
24310.75.242.0/2410.75.242.1 – 10.75.242.25410.75.242.255
24410.75.243.0/2410.75.243.1 – 10.75.243.25410.75.243.255
24510.75.244.0/2410.75.244.1 – 10.75.244.25410.75.244.255
24610.75.245.0/2410.75.245.1 – 10.75.245.25410.75.245.255
24710.75.246.0/2410.75.246.1 – 10.75.246.25410.75.246.255
24810.75.247.0/2410.75.247.1 – 10.75.247.25410.75.247.255
24910.75.248.0/2410.75.248.1 – 10.75.248.25410.75.248.255
25010.75.249.0/2410.75.249.1 – 10.75.249.25410.75.249.255
25110.75.250.0/2410.75.250.1 – 10.75.250.25410.75.250.255
25210.75.251.0/2410.75.251.1 – 10.75.251.25410.75.251.255
25310.75.252.0/2410.75.252.1 – 10.75.252.25410.75.252.255
25410.75.253.0/2410.75.253.1 – 10.75.253.25410.75.253.255
25510.75.254.0/2410.75.254.1 – 10.75.254.25410.75.254.255
25610.75.255.0/2410.75.255.1 – 10.75.255.25410.75.255.255
01 / table

IPv4 CIDR prefix table.

Click a prefix longer than your network to split it into subnets.

prefixsubnet maskaddresseshostsin your /16
/00.0.0.04,294,967,2964,294,967,294-
/1128.0.0.02,147,483,6482,147,483,646-
/2192.0.0.01,073,741,8241,073,741,822-
/3224.0.0.0536,870,912536,870,910-
/4240.0.0.0268,435,456268,435,454-
/5248.0.0.0134,217,728134,217,726-
/6252.0.0.067,108,86467,108,862-
/7254.0.0.033,554,43233,554,430-
/8255.0.0.016,777,21616,777,214-
/9255.128.0.08,388,6088,388,606-
/10255.192.0.04,194,3044,194,302-
/11255.224.0.02,097,1522,097,150-
/12255.240.0.01,048,5761,048,574-
/13255.248.0.0524,288524,286-
/14255.252.0.0262,144262,142-
/15255.254.0.0131,072131,070-
/16255.255.0.065,53665,5341
/17255.255.128.032,76832,7662 split →
/18255.255.192.016,38416,3824 split →
/19255.255.224.08,1928,1908 split →
/20255.255.240.04,0964,09416 split →
/21255.255.248.02,0482,04632 split →
/22255.255.252.01,0241,02264 split →
/23255.255.254.0512510128 split →
/24255.255.255.0256254256 split →
/25255.255.255.128128126512 split →
/26255.255.255.19264621,024 split →
/27255.255.255.22432302,048 split →
/28255.255.255.24016144,096 split →
/29255.255.255.248868,192 split →
/30255.255.255.2524216,384 split →
/31255.255.255.2542232,768 split →
/32255.255.255.2551165,536 split →
02 / faq

About this calculator.

How do I use this subnet calculator?

▼

Type an IP address followed by a prefix, like 192.168.1.10/24, or by a subnet mask, like 192.168.1.10 255.255.255.0. Without a prefix it uses /24. Click a row in the table to split the network into smaller subnets.

Why are usable hosts always 2 fewer?

▼

The first address in a subnet is the network address and the last is the broadcast address, so neither can go to a device. The exceptions are /31 (point-to-point links, RFC 3021) and /32 (a single address), which use every address.

Can I use it from a terminal?

▼

Yes. curl 'ipku.in/en/tools/ipv4-subnet-calculator?q=192.168.1.10/24' returns the result as plain text.

Learn how to work it out →